Upstream Absolute Filter Replacement (Fig. 17); Motor Cooling Fan Inspection And Cleaning; Tightness Inspection; Vacuum Cleaner Disposal - Nilfisk cfm 118 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Upstream absolute filter replacement (fig.
17)
Disassembly
-
Release the hooks "C" and lift the deck "D".
-
Unsrew the knob "G" and take the nut "F" under
the filter "E".
-
Cover the filter "E" with a plastic bag and remove
it.
-
Seal the plastic bag hermetically, insert a new filter
unit which complies with the laws in force and seal
the cover again hermetically.
Assembly
Assemble in this order:
-
the absolute filter;
-
nut and central knob for locking;
-
the deck, blocking it using the hooks "C".

Motor cooling fan inspection and cleaning

Periodically clean the motor cooling fan to prevent
the motor from overheating, especially if the vacuum
cleaner is used in a dusty place.

Tightness inspection

Hoses check
Check that the hose "A" (fig. 15) is in good condition
and correctly fixed.
If the hose is damaged, broken or badly connected to
the unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle
plate inside the filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in figure 15.
Cover tightness check
If the gasket "A" (fig. 11) under the cover "D" has
become slack, unscrew the screws "B" that lock the
closing hooks "C" in place and allow them to slide
downwards until the deck "D" closes perfectly.
Now tighten the locking screws "B".
Replace the gasket "A" - fig. 11 if the degree of
tightness is still not optimum.
Filtering chamber tightness check
If the gasket "A" - fig. 12 between the container and
the filtering chamber "C" fails to guarantee tightness:
-
loosen the four screws "B" that lock the filtering
chamber "C" against the vacuum cleaner
structure;
-
allow the filtering chamber "C" to lower down and
tighten the screws "B" once it has reached the
tightness position.
The gasket must be replaced if it is torn, cut, etc...
Replace the gasket "A" if the degree of tightness is still
not optimum.
02/2013

Vacuum cleaner disposal

Dispose of the vacuum cleaner in compliance with the
laws in force.
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The above symbol ("N", fig. 1), which is present on the
product or o in its documentation, indicates that the
product can not be disposed of with other domestic
waste at the end of its cycle of life. To prevent
damages to the environment or the health caused by
improper waste disposal, please separate this product
from other waste and recycle it responsibly in order to
support the sustainable reuse of material resources.
Domestic users should contact the retailer or the local
office providing information on separate collection and
recycling of this product. Companies should contact
the supplier and check the purchase contract terms
and conditions. This product can not be disposed of
together with other commercial waste.

Wiring diagrams

See fig. 18.
Wiring diagram list
Name
H1
Power supply light
S1
Motor switches
11
Part
Code
Z8 391275
Z8 39000
C384
118
US