Climate
Admissible relative air humidity: 92 %, non condensing.
Load in wet and alternating climate: FW 24 in accordance with DIN 50016.
Enclosure rating and safety class
Contact and moisture protection: IP 65 in accordance with IEC 529,
EN 60529, DIN VDE 0470 Part 1 Safety class 1 - electric mains with earth
Technical data of inputs (contact input, level input)
Voltage at open contacts:
Input resistance:
Short-circuit current:
Maximum level for "0" signal:
Maximum level for "1" signal:
Minimum closing time contact input: 20 ms
Response time level input:
Sound pressure level
Sound pressure level: < 70 dB(A) at a distance of 1 m in accordance
with EN 23741 or EN 23742 at maximum stoke, maximum stroke rate,
maximum back pressure (water)
Shipping weight
Shipping weight:
11
Suction lances
Adjustable suction lance with single-stage level switch, closing in the
event of lack of chemicals.
The delivery scope also includes the parts required for connecting the
pump.
Retrofit kits
* connecting parts given suction lances and tanks provided by the
ProMinent
®
Accessories
Suction lance for 200 l drum, tank opening 2" DIN 570, PPE
Suction lance for 200 l drum, tank opening 2" DIN 570, PCB
Suction lance for tank 5-50 l drum, tank opening d50, PPE
Suction lance for tank 5-50 l drum, tank opening d50, PCB
Retrofit kit External + level CNP
Retrofit kit level switch CNP*
customer
Technical data / Accessories
5 V DC ± 0.5 V
12 kΩ ± 0.5 kΩ
0.5 mA ± 0.05 mA
1.0 V
3.5 V
2 s
1.8 kg
1022511
1022512
1022645
1022644
1022099
1022115
27