9
IMPORTANT
• When decommissioning a pump, clean all traces of chemicals
• Observe all relevant disposal directives for your area
10
Output diagram at 180 strokes/min
Pump
min. output at
type
maximum
backpressure
bar
l/h
1000
10
0.74
1601
16
1.1
1002
10
2.1
0704
7
3.9
0308
3
8.5
0215
1.5
14.9
Leistungstabelle bei 240 Hüben/min
Pump
min. output at
type
maximum
backpressure
bar
l/h
1001
10
1.0
1602
16
1.5
1003
10
2.7
0705
7
5.2
0311
3
11.4
0220
1.5
19.9
* Suction lift with filled suction line and liquid end
** Suction heights with clean as well as moistened valves, with
ProMinent
®
Decommissioning and disposal / Technical data
Decommissioning and disposal
and dirt from the housing and particularly the liquid end.
(particularly with regard to electronic waste)
Technical data
min. output at mean
backpressure
ml/stroke bar
l/h
ml/stroke
0.07
5
0.8
0.1
8
1.4
0.19
5
2.6
0.36
3.5
4.5
0.79
1.5
10.8
1.38
1.0
15.5
min. output at mean
backpressure
ml/stroke bar
l/h
ml/stroke
0.069
5
1.3
0.10
8
1.9
0.19
5
3.5
0.36
3.5
5.9
0.79
1.5
14.4
1.38
1.0
23.4
metering medium water (20 °C), 100% stroke length, max. stroke
frequency, free outlet or opened vent valve and properly installed
piping system.
max. no.
Conn. size
of strokes
outer Ø •
inner Ø
Strokes/
min.
mm
0.08
180
6x4
0.13
180
6x4
0.24
180
6x4
0.42
180
6x4
1.00
180
8x5
1.4
180
8x5
max. no.
Conn. size
of strokes
outer Ø •
inner Ø
Strokes/
min
mm
0.09
240
6x4
0.13
240
6x4
0.24
240
6x4
0.41
240
6x4
1.0
240
8x5
1.63
240
8x5
Suction
Suction
Permissible
height*
height**
pre-pressure
suction side
m WC
m WC
6
1.8
6
2.0
5
2.5
4
3.0
2
2.0
1.5
1.5
Suction
Suction
Permissible
height*
height**
pre-pressure
suction side
m WC
m WC
6
1.8
6
2.0
5
2.5
4
3.0
2
2.0
1.5
1.5
bar
8
8
5
3
1
0.5
bar
8
8
5
4
1
0.5
25