Resistance Measurements / Continuity

Disconnect the UUT from all sources of supply and check that it is at zero
voltage.
1) Turn selector switch (2) to Ω/
2) Plug the black test lead into the "COM" socket and the red lead into the "+" socket
3) Connect the probes to the UUT and read the display
If the display is not visible during measurement, press the "HOLD" button (3)
to retain the display. The probes can then be removed from the conductor and
the stored value read.
Continuity: At a resistance less than 40 Ω (< 40 Ω) a signal is audible.

MIN/MAX and peak values/ Auto Power Off

The MIN/MAX button can be used to find either the largest or the smallest value of
a series of measurements. Pressing the MIN/MAX button activates first the MIN
mode, so that the smallest value is selected.
Pressing it a second time changes to MAX mode, for the largest value. Pres-
sing the button a third time returns the instrument to normal operation.