Faber VEIL Manual De Instrucciones página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Fitting the Hood canopy
• Remove the Metal grease filter using the handles provided.
• Adjust the two screws Vr, in the brackets 11a, so that they are
at the start of their travel.
• Hook the hood body to the two brackets 11a.
• From the inside of the hood body, turn screws Vr to level the
hood body itself.
• Fasten the safety screws 12a.
• Replace the Metal grease filter.
AIR OUTLET - DUCTING VERSION
When installing the Ducting version, join the Hood to the outlet
duct using a rigid or flexible pipe ø150 - ø 120 selection of which
is at the discretion of the installation technician.
• Check that the pipe is properly inserted onto the Motor Unit
outlet.
• Fix the outlet pipe using suitable pipe clamps. The materials
required to do so are not provided.
AIR OUTLET – RECIRCULATION VERSION
• Join the 2 half-elements making up the pipe 14.
• Push the pipe 14 firmly until it is all the way in.
• Cut away the excess part with a tool.
• Fix the directional Grid 8 on the recycled air outlet, using 2
screws 12e (2.9 x 9.5) provided.
• Make sure that the Activated charcoal odour filter has been
fitted.
EN
Connections
1
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Veil-col

Tabla de contenido