Page 12
SB-2-855-B
PARTS REPLACEMENT/MAINTENANCE
SEPARATOR SEAL INSTRUCTIONS
Replacing Separator Seal
1 . Remove air cap and retaining ring . (See fig 37)
2 . Remove fluid adjusting knob, spring, and spring pad .
(See figs 38 & 39)
3 . Remove fluid needle from gun body . (See fig 40)
4 . Remove fluid nozzle using SRI-50 (6 mm) wrench .
(See figs 41, & 42)
5 . Remove Separator . (See fig 43)
6 . Clean front of gun if required, using a soft brush, as
well as the fluid nozzle, air cap, and retaining ring .
7 . Place a new Separator Seal into the front of the gun,
making sure the flat side of the seal is aligned with
the flat in the gun . (See fig 44) .
8 . Fit Fluid Nozzle, Air Cap, and Retaining Ring . Torque
the Fluid Nozzle to 80-90 in-lbs (9-10 Nm) . Don't over
torque the Fluid Nozzle . (See figs 45, 46, and 37)
9 . Insert Fluid Needle all the way into the Gun Body,
seating in the Fluid Nozzle . (See fig 47)
10 . Reassemble Needle Spring, Spring Pad, and Fluid
adjusting Knob . (See fig 47)
11 . Trigger gun fully and screw in Fluid Adjusting Knob
until it stops . Back it off 1/2 turn and gun will have
full needle travel . (See fig 48)
12 . Trigger gun several times to verify correct operation .
(See fig 48)
80-90 in-lbs
(9-10 Nm)
1/2
turn