7. Technical Data
Description
Required operating pressure without
spray gun
Necessary operating pressure with spray
gun (in combination with 20 m spray air
hose Art. No. 13870)
Max. operating pressure
Required minimum volume flow
Maximum flow rate (6.0 bar, air regulator
open wide)
Operating temperature
Storage temperature
Weight
Operating pressure of compressed air
safety tube
8. First Use
The breathing protection hood is delivered in an assembled and opera-
tionally ready state.
Check after unpacking:
■ Breathing protection hood damaged.
■ Scope of supply complete (see chapter 5).
8.1. Personalise breathing protection hood
The breathing protection hood can be personalised with two CCS disks
[3-2]. The hood is supplied ex works with two red CCS disks on the right
and left bolt [3-1] of the visor.
■ Push the CCS-disks out from the inside of the hood and replace it with
CCS-disks of different colours.
8.2. Adjust head straps
The head straps have four adjustment possibilities for the individual ad-
justment to the wearer. To adjust the head straps, remove them from the
hood shell as follows.
■ Remove the hood cover [2-15] and open the visor [2-6].
■ Undo the rear fixing tabs [4-3] and release the front fixing tabs [4-1].
■ Remove head straps.
Adjust head straps to head size.
Operating instructions SATA air vision 5000
Unit
2,5 bar – 3,0 bar
4,0 bar – 6,0 bar
10,0 bar
150 Nl/min
740 Nl/min
5 °C – 60 °C
-20 °C – 60 °C
ca. 975 g
max. 10,0 bar
EN
83