Emerson White Rodgers 36J22 Manual De Instrucciones página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS
Parts and Accessories:
Natural to Regulated LP Gas Conversion Kits
• F92-0659 for Single Stage
• F92-1008 for Two-Stage
Natural to Unregulated LP Gas Conversion Kit
• F92-0737
PRECAUTIONS
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING
PRECAUTIONS.
WARNING
!
1. Failure to turn off electric or main gas
supply to heating system could cause
personal injury and/or property damage
by shock, gas suffocation, fire, and/or
explosion.
2. Do not use this control on circuits
exceeding specified voltage. Higher
voltage will damage the control and may
cause shock or fire hazard.
3. NEVER USE FLAME OR ANY KIND OF
SPARK TO CHECK FOR GAS LEAKS–
COULD CAUSE FIRE AND/OR EXPLOSION.
4. Do not use a control set for natural gas
with LP gas, or a control set for LP gas
with natural gas. Personal injury and/or
Properly install gas piping to control.
• Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.
• Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.
• Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the
supply pipe. Do not grip bracket, solenoid or any other part of control.
• Do not over-tighten pipe to control (50ft-lbs max.)
• Always install sediment trap in the gas supply line to prevent contamination of gas valve.
Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.
1. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring
can cause equipment damage, property damage, and/or personal injury.
2. This control is not intended for use in locations where it may come in direct contact with water.
Suitable protection must be provided to shield the control from exposure to water (dripping,
spraying, rain, etc.).
3. Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm-
fully with the gas valve components before install.
2
Note: Two single stage kits may be used for two-
stage valve
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
5. Do not use a gas valve which appears to be
6. Do not use a gas valve that has been in
WARNING
!
CAUTION
!
LP to Natural Gas Conversion Kits
• F92-0656 for Single Stage
• F92-1011 for Two-Stage
property damage, gas suffocation, fire,
and/or explosion may result.
damaged. A damaged valve may cause
personal injury and/or property damage
due to shock, gas suffocation, fire and/or
explosion. Contact supplier to replace any
valve that appears to have been damaged.
direct contact with water. Water entering
gas valve may result in concealed internal
damage to gas valve. Personal injury and/
or property damage, gas suffocation, fire
and/or explosion may result.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

White rodgers 36j24White rodgers 36j54White rodgers 36j55

Tabla de contenido