Error Message - effegibi Logica Twin MID Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para Logica Twin MID:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLE-SHOOTING
Please note: the information in the table below and the action to take is intended for the use of the
assistance centre personnel and others qualified to install/maintain the equipment.

Error message

Critical errors
Non-critical errors
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes
OPERATING AND MAINTENANCE MANUAL
FOR LOGICA TWIN MID
Meaning
No software dia-
logue with an ele-
ment already reco-
gnised.
The control panel is
not in dialogue with
the other electronic
elements.
New
peripheral
device recognised.
Boiler full too soon.
Boiler not yet full.
Boiler not yet
empty.
without having to give prior notice or replace this manual.
Error
Cause
Lack of
One of the devices is
communication
not receiving power
with 1 or more
or is not connected.
devices.
Lack of
One of the devices
communication
is not receiving po-
with 1 or more
wer or is not con-
devices.
nected.
A new component
has been connected
to the product.
The boiler filled
Outlet valve not
too quickly during
working.
initial rinsing or
final emptying.
The boiler didn't
Lack of water in
fill within the
the system or the
prescribed time
inlet valve filter is
limit during initial
blocked.
rinsing or final
emptying.
The water level in
Outlet
the boiler remained
working.
too high for too
long during initial
rinsing or final emp-
tying.
Solution
1. Check the device
connections.
2. Run the start-up
sequence.
1. Check the device
connections.
2. Run the start-up
sequence.
1.
Check
connections
power cabling.
2. Run the start-up
sequence.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.
1. Check that the
water tap is turned
on.
2. Check that there
is water in the
system.
3. Check that
the filter at the
entrance to the
inlet valve is not
blocked.
valve
not
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.
EN