EN-24
3.5.2 Zero Range
Set the percentage of scale capacity that may be zeroed.
2%
100%
NOTE: The setting is forced and locked to 2% when the Security Switch is set to the locked position.
3.5.3 Filter Level
Set the amount of signal filtering.
Low
= faster stabilization time with less stability.
Medium
= normal stabilization time with normal stability.
High
= slower stabilization time with more stability.
3.5.4 Auto Zero Tracking
Set the automatic zero tracking functionality.
OFF
0.5division
1d
3d
3.5.5 Auto Dim
Set the display backlight functionality.
Settings:
1 min = backlight turns off after 1 minute of no activity.
2 min = backlight turns off after 2 minute of no activity.
5 min = backlight turns off after 5 minute of no activity.
10 min = backlight turns off after 10 minute of no activity.
Always on
Off
3.5.6 ScreenSaver
Set whether the screensaver is enabled after the selected time period.
Off = Disabled.
5 min = the screensaver is enabled after 5 minutes.
10 min = the screensaver is enabled after 10 minutes.
30 min = the screensaver is enabled after 30 minutes.
3.5.7 Auto Off
Set whether the display enters sleep mode after the selected time period.
Off = Disabled.
5 min = the display enters sleep mode after 5 minutes.
10 min = the display enters sleep mode after 10 minutes.
30 min = the display enters sleep mode after 30 minutes.
= disabled.
= the display will maintain zero until a change of 0.5 division per second has
been exceeded.
= the display will maintain zero until a change of 1 division per second has
been exceeded.
= the display will maintain zero until a change of 3 divisions per second has
been exceeded.
Defender 5000 Indicators