Problem
Motor gets too warm
(Temperature
measurement)
Motor noise too loud
Notes:
Antriebe Typ 63 - 200L
Version: 27217 / A
Possible cause
Overload
Insufficient cooling
Motor wired in delta
instead of star
Supply
line
has
problem (two-phase
operation)
Fuse triggered
Line
voltage
varies
nominal rating by more than
10%
Nominal
operating
exceeded (S1 to S9, DIN
57530),
for
example
switching too frequently
Roller
bearings
soiled
defective
Vibration due to imbalance
Wear on the pump
Schmalenberger GmbH + Co
D-72013 Tübingen - Germany
Solution
Measure power; check motor & pump
design if appropriate
Ambient temperature too high; clean
cooling air passages
Correct wiring
contact
Correct loose contact, re-tighten
terminals
Replace fuse, find and correct cause
from
Using approriate
voltage to rated voltage of motor;
change motor if necessary
mode
Match nominal operating mode of the
motor to the operating conditions; if
by
necessary design a new drive
or
Check and/or replace roller bearings
Correct imbalance
General overhaul of motor and pump