safety precautions and usage statements
increase, the vibrations change concurrently .
_________________________________________________________________
Bed Tolerance
TOLERANCE
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
(β°)
The angle (designated "α" in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½".
The angle (designated "β" in figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾".
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer's
foundation is to be operated with a mattress and load . Testing procedures
quality control standards.
Blake Pettit
require lifetime cycle tests with up to 120kg distributed load . The angle
Quality Assurance Manager
Ph 805-979-3875
Fx 805-979-9399
(designated "a" in figure 1) between the back section and the flat section
www.ergomotion.com
for various configurations of the mattress support platform shall be ± 3°,
which translates to a tolerance of up to 1 ½" .
Ergomotion Inc.
|
ph 1-888-550-3746
|
fx 805-979-9399
|
www.ergomotion.com
The angle (designated "b" in figure 1) between the flat section and foot
section for various configurations of the mattress support platform shall be
± 3°, which translates to a tolerance of up to ¾".
Any adjustable foundation deemed to be within these allocated tolerances
is considered to have met the manufacturer's quality control standards .
THAT "NEW PRODUCT" SMELL:
Some people notice a slight odor to their new adjustable base—this can
come from our material manufacturing process . This smell is normal and
Adjustable
All Ergomotion adjustable
foundations, depending on make
and model, are designed and
manufactured to perform and
(α°)
function within designated quality
control parameters . Bases are
subject to meticulous and rigorous
inspections during the quality
control process to ensure bases
will operate within these standards
during normal operating use .
Normal operating use is defined
as the following: Adjustable
usually disappears before the product reaches you . Sometimes, however,
this smell may still be noticeable . It usually disappears after a few weeks,
providing adequate ventilation of the product and the environment .
BREAK IN PERIOD:
You can speed up the break-in period by simply spending time in the
adjustable bed through activities such as reading, watching TV or playing
with the kids or grandkids . The extra movement will help the adjustable
base respond to weight and temperature changes . Some of the materials
in our adjustable bases such as the woods, metals and plastics used in
the platform, frame and components are sensitive to moisture content and
temperature and may make sounds in colder environments .
PAIRED OPERATION:
When operating a "paired" split base setup there may be a time latency up
to 1 .5 seconds between each bases articulation .
WEAR AND TEAR:
Wear and tear is damage that naturally and inevitably occurs as a result of
normal use or aging .
FABRIC CARE:
To prolong the life of your fabric, protect from direct sunlight whenever
possible . For spot cleaning, wipe area with a light damp sponge or vacuum
with a soft brush attachment to remove particles . Keep at a minimum of
30cm (12 inches) away from direct heat sources . For a deeper cleaning,
blot liquid spills with a clean dry cloth . Wipe with a clean cloth dampened
with warm water . Do not wet excessively . A soft bristle brush may be used
to remove ingrained soil . Avoid scratching by gentle brushing . Wipe with a
clean cloth dampened with warm water to remove residues . Dry in shade
away from direct heat . If persistent marks remain visible after cleaning, seek
professional advice .