Fuse Check/Replacement; Accessories/Options; Trouble Shooting - Viper AS530R Manual De Usuario

Ocultar thumbs Ver también para AS530R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER MANUAL

FUSE CHECK/REPLACEMENT

1.
Turn the key switch (D, Figure 24) to "OFF".
2.
Disconnect the battery connect cable.
3.
Unscrew the screws (C) on the control panel and then turn over
the PCBA to find the fuse (A and B).
4.
Check/replace the fuses:
A) F1 is the low-power circuit fuse (5A)
B) F3 is brush dismount fuse (20A)
5.
After check/replacement is done, re-assemble in the reserve
order of dismount.
6.
Check or reset the motor overload protector.
E) F5 is vacuum motor overload protector (30A)
F) F4 is drive motor overload protector (30A)
G) F2 is brush motor overload protector (30A)

ACCESSORIES/OPTIONS

In addition to the standard components, the machine can be equipped
with the following accessories/options, according to the machine
specific use.
For further information concerning the above mentioned optional
accessories, contact an authorized retailer.
Accessories/Options
See "Parts List" section
1.
GEL/AGM batteries
2.
Pads of different materials

TROUBLE SHOOTING

Trouble
The motors do not work; no warning
light turns on (C9)
The machine do not work, red battery
capacity warning light turns on (C8)
The machine do not go-forward /
backward
The brush motor does not work
The drive motor does not work
The vacuum motor does not work
Probable causes
The battery connector is disconnected
The batteries are completely discharged
The batteries level is too low
The control circuit board fault
The drive motor controller fault
The operator not on the seat
Squeegee is not lifted during machine
goes backward
The control circuit board fault
Brush motor overload
Brush motor contactor fault
Brush motor carbon brush wearing
Obstacles prevent the brush rotating
Drive motor trouble light turns on
Drive motor overload
Vacuum motor overload
Relay of vacuum motor fault
19
B
A
E
F
G
Figure 24
Remedy
Connect the battery connector
Charge the batteries
Charge the batteries
Replace the control circuit board
Refer to "DRIVE MOTOR ERROR
INDICATOR INFORMATION"
Sit on the seat
Lift the squeegee
Replace the control circuit board
Use soft bristle brush that is
suitable for cleaning, and reset the
brush motor overload protector
Contact after-sales service
Contact after-sales service
Clean the brush
Refer to "DRIVE MOTOR ERROR
INDICATOR INFORMATION"
Reset drive motor overload
protector and check drive
motor/circuit
Reset vacuum motor overload
protector and check vacuum motor
Contact after-sales service
ENGLISH
C
D

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

50000417

Tabla de contenido