1.CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete
draining.
CAUTION:
Make sure to turn the engine switch and the fuel cap vent lever to the
OFF position before draining.
1.Loosen the cover screw and remove the left side maintenance cover.
2.Remove the oil filler cap.
3.Drain dirty oil into a suitable container thoroughly.
4.Refill with the recommended oil (see page 16) and check the oil level.
5.Wipe off all the spilled oil from the generator.
6.Reinstall the left side maintenance cover and tighten the cover screw
securely.
COVER SCREW
LEFT SIDE MAINTENANCE COVER
OIL FILLER CAP
UPPER LEVEL
OIL FILLER HOLE
Wash your hands with soap and water after handling used oil.
NOTE:
Please dispose of used motor oil in a manner that is compatible with
the environment. We suggest you take it in a sealed container to your
local service station for reclamation. Do not throw it in the trash or pour
it on the ground.