Description; Product Overview; Feature Description; Intended Use - Dräger FPS 7000 Instrucciones De Uso

Ocultar thumbs Ver también para FPS 7000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
2

Description

2.1

Product overview

Facepiece (see Figure Z1 on page 263)
Connector type (see Figure Z2 on page 263)
1
Visor frame, top
2
3
Adjuster buckle
4
5
Facepiece body
6
7
Cap
8
9
Nose cup valve
10 Nose cup
11 Visor
12 Connector
13 Button
14 Speech diaphragm
15 Exhalation valve seat
16 Exhalation valve spring
17 Spring holder
18 Exhalation valve disc
19 Inhalation valve disc
20 Clamping ring
and valve seat
21 O-Ring
2.2

Feature description

Dräger FPS 7000 facepieces are available with the following
connectors:
round thread connection RD40x1/7" according to EN 148-1
RA
for canisters
plug
connection
(Dräger-specific)
P
breathing apparatus or air line breathing apparatus
Dräger FPS 7000
Special facepiece spectacles are available for users who wear
spectacles.
Instead of the harness a special hairnet can be used.
The facepieces can be used within a temperature range between
-22 °F to 140 °F (-30 °C to +60 °C). Lower or higher temperatures are
permitted when the exposure time is short.
Head harness
2.3
Neck strap
The facepieces of the Dräger FPS 7000 series protect the face and the
eyes against aggressive media. They must only be used with NIOSH-
Exhalation valve cover
approved self-contained breathing apparatus, air line breathing
Visor frame, bottom
apparatus, or canisters.
2.4
The facepieces in combination with self-contained breathing
apparatus, air line breathing apparatus, or canister have been
certified by NIOSH in compliance with title 42, Code of Federal
Regulations, Part 84. Only combinations that are approved by NIOSH
may be used in the USA (see "Approval Label" on page 262 for
masks with Rd40 connector for use with filters and canisters. Labels
for SCBA sets can be found in the Instructions for Use of the SCBA
sets).
Furthermore, the facepieces are approved according to EN 136:1998
CL.3+ and are marked with the CE mark of conformity. In addition, they
meet the flame engulfment requirements stipulated in EN 137.
The Dräger FPS 7000 RA facepieces are also approved in Australia
and New Zealand according to AS/NZS 1716:2012.
for
self-contained
(Use Instructions for NIOSH-approved full facepieces)

Intended use

Approvals

Description
251

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fps 7000 s-fixFps 7000 q-fix

Tabla de contenido