Extraction Arm on Hinged Cantilever

Art. Nr.: 1502199
Hinged Cantilever
Assembly
WARNING
Falls and falling components can cause serious
injuries.
The extraction arm is mounted at a height of approximately
2300 mm. By improper handling you and/or the components
may fall.
● Use appropriate ascending aids or working platforms.
● Do not stand or walk under suspended loads.
Fig. 2-6
● Place the flat rubber seal (22) onto the flange of the
slewing ring (23) at the end of the extraction arm (24).
● Screw the flange of the slewing ring (23) with eight screws - M6
x 25 - 8.8 - and nuts (25) with the flat rubber seal (22) on the
mount bracket for the exhaust arm (26).
2-6