König Electronic SEC-ALARM100 Manual De Uso página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
b) Push the ON button on the remote control to arm the alarm.
c) Wait for 20~25 seconds (delay time).
d) For testing door/window sensor, open every door or window one by one and check if the
corresponding LED lights up and the CHIME sounds.
e) For testing PIR sensor, move around the PIR sensor and check if the corresponding LED lights
up and the CHIME sounds. Note: the LED indicator on the PIR sensor lights up also.
f) Disarm the alarm if everything operates correct.
g) The alarm system is ready to use.
Note:
1) The alarm unit will give a conformation tone when armed or disarmed. The tone for CHIME is
different as for ALARM.
2) If a sensor does not need to be switched on, it's possible to switch off every sensor individually with
the on/off switch. In this case the sensor is no part of the alarm system anymore when armed
(except PIR sensor).
3) A sensor switched to RF+ALARM will always give an alarm sound on the sensor itself, unless the
alarm unit is armed or disarmed.
4) When a sensor is triggered and the siren of the alarm unit sounds, it needs to be switched off with
on/off switch of the alarm unit. After that the alarm unit can be switched on again. When the alarm
keeps on going after arming the system, check if every sensor is installed properly.
Specifications:
Alarm unit (figure 1):
Power: 4.5 VDC (3x battery AA, not included)
Standby current: <1.5 mA
Chime current: <90 mA
Alarm current: <130 mA
Alarm volume: 100 dB (0.5m)
Chime volume: 90 dB (0.5m)
Switch: alarm/chime/off
LED indicator: 6
Frequency: 433 MHz ±250 kHz
Dimensions: 5.7(W) x 3.9(D) x 10.9(H)cm
Delay time: 20 ~ 25 sec.
Door/window sensor (figure 2):
Power: 4.5 VDC (3x battery LR44, included)
Standby current: <10ηA
Transmission current: <6 mA
Working distance: +/- 60 m (open area)*
Alarm volume: 95 dB (0.5m)
Switch: RF + alarm/RF/off
Frequency: 433 MHz ±250 kHz
Dimensions with magnet contact: 6(W) x 1(D) x 9.9(H)cm
PIR sensor (figure 3):
Power: 4.5 VDC (3x battery AA, not included)
Standby current: <100ηA
Transmission current: <5mA