Technical data

Dimensions
Weight
Pressure-bearing volume
Cartridge length
Cartridge diameter
Ambient temperature
Input pressure
Internal working pressure
Conversion ratio, pressure amplification
Safety valve
Compressed air
Compressed-air connection
Materials of the pressure-bearing parts

2. Safety instructions

General safety notes

The device is a state of the art piece of equipment and has been constructed according to recognised safety specifica-
tions. It is nevertheless possible that use of the device will present hazards to the operator or to third parties, or may
damage the device or other property. It is therefore essential to act in accordance with these operating instructions, and
in particular with those sections identified as warnings.
Warnings and symbols
In the operating instructions, the following signs are used for highlighting important information.
Special information for economical use of the equipment.
Special information or "dos and don'ts" for damage prevention.
Information or "dos and don'ts" for the prevention of damage to persons or equipment.
Appropriate use
The device may only be used if it is in perfect condition, and then only for its intended purpose, in compliance with
all safety regulations, with an awareness of the potential risks, and according to the operating instructions. Any
faults that may impair the safety must be rectified immediately.
The equipment is intended exclusively for the the use described. Using the machine for any other purpose would
constitute inappropriate use. The manufacturer is not responsible for any loss arising as a result of this, the risk for
this is borne only by the operator.
Organisational measures
This operating manual should always be kept readily available at the site of operation! It is essential that the
type plate and the warnings attached to the device are observed, and are maintained in a fully readable condi-
tion.
Qualified Personnel
Persons who operate or maintain the equipment must have the qualification applicable to this work. The areas
of responsibility, competences and supervision of the personnel must be precisely regulated by the operator.
The operator must also ensure that the contents of the operating instructions are properly understood by the
personnel.
Servicing and Maintenance
Do not perform any modifications, additions or conversion on the equipment without the approval of the manu-
facturer. Spare parts must comply with the technical requirements specified by the manufacturer. This is al-
ways assured if original spare parts are used.
GB
approx. 540x250x100 mm
approx. 1.6 kg
approx. 1.3 litres
214 mm - 220 mm
45 mm -50 mm
0 ° C ... +55 ° C
max. 10 bar
adjustable via regulator valve 0.5 - 7 bar
3 : 1
Safety valve release pressure - 8 bar
contamination-free, dry, lubricated
pin for coupling system DN7,2
PA6, glass fibre reinforced