CONTROL PANEL AND OPERATION METHOD
BT25
OPERATION AND FUNCTION ILLUSTRATION
ON/OFF button:
Press the „ON/OFF" button once, the green light is on and device starts work.
Press it again, the green light is off and device stops running.
If you start the device again, the green light will flash, and device will auto start
3 minutes later.
MODE button:
It is used to choose high speed and low speed.
Meanwhile, the indicator light on the panel will be on.
It is on high speed if you turn on the device for the first time.
HIGH and LOW indicator lights:
a) when the lights are on, it means the fan speed that has been chosen
b) when the lights flash, it means the temperature sensor is broken (open-circuit or
short-circuit).
„Defrost/Tank-full" indicator:
If the Defrost indicator (red) keeps on and the On/Off/Standby indicator (green) flashes,
it means the device is defrosting.
The unit returns to work after defrosting.
If the red indicator and the green indicator flash simultaneously, it means the water
bucket is full.
The unit will stop for 3 minutes after taking out the bucket.
Please put the bucket back to the unit in 3 minutes, or the unit will resume working
automatically and water will flow into the unit.
If it is less than 3 minutes, it will postpone working until it reaches 3 minutes.
ON/Off
Defrost
High
Standby
Tank full
RH
Indicator
EN
Low
RH