"Hydronic Global Cassette" Fan Coil Units

Legend

Fig.1.
A
-
Unit
B
-
Frame/Grille assembly
Fig.15.
1 -
Heating: louvre position for correct air flow
2 -
Cooling: louvre position for correct air flow
Warning
To close one or two air outlets use the special kit
Fig.18.
1 -
Nut
2 -
Wooden frame
3 -
Threaded hangers
4 -
Washers
5 -
Nut
6 -
Washers
7 -
Threaded hangers
8 -
Washers
9 -
Nut
10 -
Nut
Fig.19.
7 -
Threaded hangers
11 -
"T" bar (to be removed)
Fig.20.
7 -
Threaded hangers
11 -
"T" bar (to be removed)
12 -
Suspension brackets
18 -
Electrical box
Fig.21.
13 -
False ceiling
14 -
Spirit level
Fig.24.
15 -
Frame pre-hooking support
16 -
Safety belt
17 -
Frame supporting nuts and spacers
30
42GW
Fig.25.
3 -
Gasket "A"
4 -
Gasket "B"
5 -
Air discharge
Fig.26-27.
a -
Cold circuit water inlet
b -
Cold circuit water outlet
c -
Air purge valve
d -
Hot circuit water inlet
e -
Hot circuit water outlet
Fig.28.
See section "Motorized valve"
Fig.31.
Automatic operation position
f -
Valve body
g -
Thermo-electric valve head
Fig.32.
Electric heater protections
A -
Manual reset thermostat
B -
Automatic reset thermostat
Fig.35.-36. Standard.
18 -
Electrical box
19 -
Cable holder
20 -
Terminal block
21 -
Electric heater relay
22 -
Capacitor
24 -
Valve cable inlet
Fig.37. Standard with valves
25 -
Power supply cable
26 -
Control cable
27 -
Cold valve cables
28 -
Hot valve cables (4 pipes only)
Fig.39e. Brush less motor with heaters
Fig.39h. 24V valves and electric heaters
Fig.40e.
Winter operation diagram with fresh air intake
O -
Antifreeze thermostat
P -
Speed controller
Q -
Fresh air fan motor
R -
Relay 230V
a= neutral
b= cooling signal 230V
c= heating signal 230V
Fig.43.
30 -
Minimum temperature sensor (optional)
31 -
Air sensor
33 -
Internal temperature sensor
34 -
Dip-switch selector
Fig.44.
Air intake grille
J -
Wall
K -
Undercut door
L -
Wall-fitted grille
M -
Door-fitted grille
Fig.45.
j -
Duct connection flange
k -
Clip
l -
6 mm neoprene gasket
m -
Insulated flexible duct
n -
Fresh air intake
o -
Conditioned air supply to an adjacent room
Fig.47.
Diagram of conditioned air supply to an adjacent
room: one louvre closed
S -
Supply air duct to adjacent room
In case of two louvres closed, the fresh air flow towards the
adjacent room is 50% higher compared with only one louvre
closed (with equal static external pressure)