Troubleshooting Guide & Pool Pump Disassembly & Storage - Polygroup SUMMER WAVES Manual Del Usuario

Sistema de agua salada
Ocultar thumbs Ver también para SUMMER WAVES:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING:
UNPLUG THE POWER CORD BEFORE TROUBLESHOOTING THE SALT WATER SYSTEM.
SYMPTOM
A
Unplugged unit
B GFCI breaker tripped
System does
C Low voltage
not power on
D In standby mode, LED blinks
once every 5 sec.
A Electrolytic cell connectors are loose
B
Flow sensor failure, water flow
red LED is on
System
unoperational
C Filter in cell case inlet is dirty
D Timer off, back to standby mode
A
Low salt level, low salt level LED indicator on
B High salt level, high salt level LED indicator on
C Poor electrolytic cell condition,
orange LED indicator on
Chlorine level
problem
D Electrolytic cell failure, red LED indicator on
E Incorrect inlet and outlet hose direction
A Cell to pump hose
B Poor cell inlet connection
C Cell's outlet tube to pool hose
Water leakage
D Cell case to tube lock nut
E The cell unit O-ring
POOL PUMP DISASSEMBLY & STORAGE
1. First, unplug the Power.
2. Slowly unscrew the Vent Screw, Loosen all 2 Hose Clamps.
3. Clean and dry the cell parts.
4. Store the salt water system and cell unit parts carefully.
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
20
TROUBLESHOOTING GUIDE
CAUSE
MST. Extended operating days and hours during peak season requirements.
A Unit must be plugged into a 3-wire grounded outlet.
B Reset circuit breaker. If problem persists, check power circuit.
C Check line voltage - must be 105 to 125 AC volts.
D Press the standby button for 2 second to turn on the unit.
A Ensure the cell connecter is plugged and cap is screwed (see page 18 )
B Clean the cell tube (see page 13) or replace the cell unit
C Clean (see page 18) or replace fliter.
D Turn on the unit.
A Add salt to water, adjust until LED indicator turn green.
B Partially drain the pool, refill with fresh water and adjust until LED indicator turns green.
C Recommend to replace cell with new unit.
D Replace a new cell unit immediately.
E Check the direction of inlet and outlet to the salt water system.
A Tighten hose clamp with strainer grid.
B Check O-ring for damage. Replace if needed and lubricate with petroleum jelly.
C Adjust hose clamp, check O-ring. Check hose for any holes or cracks.
D Make sure top and bottom case are screw tigh with cell cover nut. (see page 19)
E Check O-ring for damage, replace if needed and lubricate with petroleum jelly.
SOLUTION

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

P5e000400000Summer waves p5e000400000

Tabla de contenido