Descargar Imprimir esta página

GRE 777590 Manual De Instrucciones página 38

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
10. Maintenance
(1) You should check the water supply system regularly to avoid the air entering the system and occurrence
of low water flow, because it would reduce the performance and reliability of HP unit.
(2) Clean your pools and filtration system regularly to avoid the damage of the unit as a result of the dirty of
clogged filter.
(3) You should discharge the water from bottom of water pump if HP unit will stop running for a long time
(especially during the winter season).
(4) In another way, you should check the unit is water fully before the unit start to run again.
(5) After the unit is conditioned for the winter season, it's recommended to cover the heat pump with special
winter heat pump.
(6) When the unit is running, there is all the time a little water discharge under the unit.
(7)R410a pressure and temperature mapping table
Condition
Ambient Temperature
Water temperature
Pressure gauge reading
Condition
Ambient Temperature
Water temperature
Pressure gauge reading
Moins 5-5 ℃
/
0.68-0.93
MPa
/
/
10-15
15-20
1.3-1.8
1.5-1.9
MPa
MPa
FLUIDRA GLOBAL DISTRIBUTION S.L.
Carrer Ametllers, 6 | 08213 Polinyà (Barcelona) | Spain
Tel.: + 34 93 724 39 00 | Fax: + 34 93 713 33 84
NIF:B63216121 -
Power OFF
5-15 ℃
15-25 ℃
/
0.93-1.25
1.25-1.64
MPa
MPa
Running (Heating)
/
20-25
1.6-2.3
MPa
www.fluidra.com
- 35 -
25-35+ ℃
/
/
1.64-2.1
MPa
/
25-30
30-35+ ℃
1.9-2.8
2.1-3.5
MPa
MPa
/

Publicidad

loading

Este manual también es adecuado para:

777591778375778392778393