If you choose to use the Dehumid function, This will remove excess moisture
from the air on excessively humid days,
Tr temperature inside the room,
Ts: the set temperature.
1) When Tr>Ts+3°F, t he compressor will run continuously the fan at the
selected speed.
2)When Tsol°F_<Tr_<Ts+3°F
the compressor will cycle for 10 minutes on
end 6 minutes off.
3)When Tr<Tsol ° F,the compressor will shut off,
The dehumidification process takes pJace between the set temperature _1
and 3°F above the set temperature, (See Fig # 5)
Fig. # 5
ControJ Panel
For cod days you may want to run the "Fan Only" function. Here the fan
runs onJy at one of 2 speeds, Meal or Lo. The fan will not run at the High
speed. (See Fig. # 6)
Fig # 6
¢ontroj
Panel