Wall Hns_aHations:
slide-out chassis only
Note Remove the 2 shipping screws on the top of the air condNoJtler
that hdd the chassis to the oater shell casing. Once removed,
these do not have to be reoinstalled. To ensure that your air
conditioner is properJy instalbd in the wall, it is recommended
that it be installed by a certified technician who is familiar with
through the wall installations.
1) Using wood, 1" or more in thickness, build a wooden frame to fit the
casing!cabinet dimensions of the unit which you have purchased.
2) Measure the outside width and the height of the frame to determine the
cutout dimensions necessary for the opening in the wall The depth of the
frame will depend on the depth of the wall The finished frame must be set
in the inside wall. The frame has to be squared and leveled Remember the
frame has to be nailed securely to the wall studs {See Fi9 # 191
wall
Fig. # 19
3) Now to install, insert the casing into the wall opening. (Removethe
chassis out first following steps 1 - 6 in Slide-out chassis sectionI.
Make sure that the cabinet is at bast 1/2" inch inside the room. Also the
side JouversshouJd not be bJocked This is to have proper air circuJation in
and around the compressor. (See Fig # 20)