Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct
Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected
to
green ground
connector.
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securely
tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1.
Disconnect
power.
2.
Remove the hold-down
screw
and terminal
block
cover.
B%
A
/
A. Neutral
ground
wire
B. bxternal
ground
conductor
screw
C. Ce,nter, silver-colored
terminal
block screw
D. 7_'rminal b lock cover and hold-
dOWl}
5CE_'W
3_
Install strain relief.
Style 1 : Power supply
cord strain relief
•
Remove the screws from a %" (1.9 cm) U[. listed strain relief (U[ marking
on strain
relief).
Put the tabs of the two clamp
sections
into the hole below
the terminal
block
opening
so that one tab is pointing
up and the other is pointing
down,
and hold in
place. Tighten
strain relief screws enough
to hold the two clamp
sections together.
,;
......................................................
A
!
1
/-
/
"...:::;
_
....................
..............................
D
A. Strain
r_qief tab pointing
up
B. Hole below
terminal
block
opening
C. Clamp
section
D. Strain
relief tab pointing
down