4-wire
connection:
Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do
not permit the use of 3-wire connections.
B
F
C
D
E
G
1,
2.
A. 4-wire
receptacle
(NEMA
type
14-30R)
B. 4-prong
plug
C. Cround
prong
D. Neutral
prong
E. Spade' te'rn'linal_
with
upturned
ends
F. Y4" ( 1.9 cn'l) Ut listed strniu
relie'f
C. Ring te'nTlinab
Remove
center
silver-colored
terminal
block
screw.
Remove
neutral
ground
wire
from
external
ground
conductor
screw.
Connect
neutral
ground
wire
and
the
neutral
wire
(white
or center
wire)
of power
supply
cord
under
center,
silver-colored
terminal
block
screw.
Tighten
screw.
A. Fxte'rnal ground
conductor
scre'w - Dotted
line shows position
of NEUTRAL
ground
wire" before
being
moved
to center
silver-
colored
terminal
block screw.
B. C_'nte'r silver-colored
te'rminal
block
screw
C. Neutral
ground
wire
D. Neutral
wire" (white
or center
wire')
E. Y4" (t.9
cm) UL li_ted strain
re'fief
3.
Connect
ground
wire !green or bare) of power
supply
cord to external
ground
conductor
screw. Tighten
screw.
4,
A. £xte'rnal
ground
colTductor
screw
B. Ground
wire' (green
or bare') of power
supply
cord
C. _"
( 1.9 cm) U_ listed strnin
relief
D. Center silve'r-colored
t_'rminal
block
screw
E. Neutral
ground
wire
I_. Neutral
wir_" (white
or center
wire')
Connect
the
other
wires
to outer
terminal
block
screws.
Tighten
screws.
!! !!
5.
Tighten
strain relief screws.
6.
Insert tab of terminal
block
cover into slot of dryer rear paneh Secure cover with
hold-
down
screw.
7.
You have completed
your electrical
connection.
Now go to "Venting
Requirements."
4-wire
connection:
Direct
wire
IMPORTANT:
A 4-wire
connection
is required
for mobile
homes and where
local codes do
not permit
the use of 3-wire
connections.
Direct
wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved
if needed.
12