2.
3.
Place the hooked end of the neutral
wire (white or center
wire) of direct wire cable under
the center screw of terminal
block
(hook facing right). Squeeze
hooked
end together.
Tighten screw.
A. [xternal
ground
conductor
screw
B. Neutral
ground
wire
C. C_q_ter silver-colore'd
terminal
block
scr_'w
D. Neutral
wire (white
or cente'r wired
E. _"
(t.9
cm) Ut li_ted strain
r_'lief
Place
the
hooked
ends
of the
other
direct
wire
cable
wires
under
the outer
terminal
block
screws
(hooks
facing
right).
Squeeze
hooked
ends
together.
Tighten
screws.
!! !!
4.
Tighten strain relief screw.
5.
Insert tab of terminal
block
cover into slot of dryer rear panel. Secure cover with
hold-
down
screw.
6.
You have completed
your electrical
connection.
Now go to "Venting
Requirements."
Optional
3-wire
connection
Use for direct wire or power supply
cord where local codes do not permit connecting
cabinet-ground
conductor
to neutral wire.
1.
Remove center
silver-colored
terminal
block
screw.
2.
Remove
neutral
ground
wire from external
ground
conductor
screw. Connect
neutral
ground wire and the neutral
wire (white or center
wire) of power
supply cord/_ able under
center, silver-colored
terminal
block
screw. Tighten
screw.
A
.......................
B
//
.....................
D
A. Fxternal ground conductor screw
B. C_'nter silver-colore'd terminal block scre'w
C. Neutral ground wire
D. Neutral wire" (white' or center wire)
E. _" ( 1.9 cm) Ut listed strain relie'f
£ Grounding path de'te'rmined by a qualified electrician
3.
Connect
the other wires to outer terminal
block screws. Tighten
screws.
!! !!
4.
Tighten strain relief screws.
5.
Connect
a separate
copper
ground
wire from the external
ground
conductor
screw to an
adequate
ground.
6.
Insert tab of terminal
block
cover into slot of dryer rear panel.
Secure cover with
hold-