Re-pressing is always necessary if a pressing operation has not been fully completed. Check
the system supplier's instructions to ascertain whether re-pressing is permitted. If it is permitted,
please note the following differences from the initial pressing operation that must be complied
with.
Information!
Ensure there is no gap between the segments of the press collar when
the pressing operation is complete.
In order to start the process, press the start button and hold it down.
After the pressing operation has been completed, open the adaptor jaw using the grip
and detach it from the press collar.
Open the press collar and remove it.
WARNING!
Risk of injury from breaking claws on the adaptor jaw and damaged pins
on the press collar
Holding the press device incorrectly and changing its position before and during re-
pressing means that the claws can no longer grip the pins properly.
The tips of the claws may press directly on the pins, causing the claws and pins to
break and fragments to fly off.
Therefore
– After positioning on the press collar, press the jaw levers on the adaptor jaw
together as far as possible using the grip. (Fig. 12)
– Make sure that the claws of the adaptor jaw always grip the press collar pins
throughout the re-pressing operation. (Fig. 11)