Carrier 80AWX Serie Manual De Instalación página 20

Ocultar thumbs Ver también para 80AWX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 87
Code
Level
Variable Name
Nr.
106
Inst.
INTERFACE CONFIG
FLOW SWITCH
107
Inst.
CONFIGURATION
MASTER OUTPUT
108
Inst.
CONFIGURATION
SLAVE OUTPUT
109
Inst.
CONFIGURATION
20
Use Days button to select below mentioned functions:
0. Domestic hot water input - configuration
0: Contact close: Input is active/contact open: Input is not active
1: Contact close: Input is not active/contact open: Input is active
1. Space heat/cool ON/OFF input - configuration (no impact on Domestic Hot Water
production)
0: Contact close: Unit produces space htg/clg/contact open:
Unit does not produce space htg/lg
1: Contact close: Unit does not produce space htg/clg/contact
open: Unit produces space htg/clg
2. Heat/Cool selection input-configuration
0: Contact close: Unit performs space heating/contact open:
Unit performs space cooling
1: Contact close: Unit performs space cooling/contact open:
Unit performs space heating
3. High energy rate input - configuration
0: Contact close: High energy rate/Contact open: Normal energy rate
1: Contact close: Normal energy rate/Contact open: High energy rate
4. External HTG/CLG
0: Mode (Heat/Cool) is determined by dry contact
1: Mode (Heat/Cool/OFF/Domestic Hot Water) is determined by user interface
(106.2 is ignored)
5. Cool Z1
0: Cool in Zone 1 forbidden
1: Cool in Zone 1 permitted
6. Cool Z2
0: Cool in Zone 2 forbidden
1: Cool in Zone 2 permitted
7. System ON/OFF input - configuration
0: Contact close: System OFF/Contact open: System running
1: Contact close: System running/Contact open: System OFF
Use Days button to select below mentioned functions:
0. (used for service purposes only)
0: Open - flowing/Short: Not flowing
1: Short - flowing/Open: Not flowing
1.
0: Do not allow water flow when the unit pump is OFF (no external pump used)
1: Allow water flow when the unit pump is OFF (external pump used)
Use UP/Down buttons to select between 1 to 10:
1. Fan Coil - Fan coils do not work when Domestic hot water valve is activated
2. Fan Coil - Fan coils are always working
3. Fan coils do not work when Domestic hot water valve is activated, unless the mode is
Cool
4. Dehumidifier
5. All alarms
6. Alarms stop the outdoor unit
7. Alarms stop the entire system
9. Defrost
10. All alarms + Defrost
11. Alarms stop the outdoor unit + Defrost
12. Alarms stop the entire system + Defrost
13. Not used
14. Not used
15. Not used
16. Not used
Use Days button to select below mentioned functions:
0
0. 3-way valve
1. Others
1
0. Zone 1: Fan coils do not work when Domestic hot water valve is activated
1. Zone 1: Fan coils are always working
2. Zone 1: Fan coils do not work when Domestic hot water valve is activated, unless the
mode is Cool
3. Zone 1: Dehumidifier
2
0. Zone 2: Fan coils do not work when Domestic hot water valve is activated
1. Zone 2: Fan coils are always working
2. Zone 2: Fan coils do not work when Domestic hot water valve is activated, unless the
mode is Cool
3. Zone 2: Dehumidifier
DESCRIPTION
VALUE RANGE
DEFAULT
Min
Max
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
16
4
1
3
0
3
3

Publicidad

Tabla de contenido
loading

Tabla de contenido