Care Instructions; Technical Data - Eschenbach maxEVENT Manual De Instrucciones

Ocultar thumbs Ver también para maxEVENT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
z Make sure that other people and
especially children are aware of this.
z maxEVENT must not be used for
driving in traffic!
z Protect your maxEVENT from impact
and excessive heat! Never place the
maxEVENT on heaters or in sunlight.
Earpiece adjustment
The plastic earpieces w can be bent in
the desired position without warming.
An internal metal wire ensures that the
earpieces remain in this position.
Adjustment
The maxEVENT is designed for a distance
of about 10 m and offers a diopter ad-
justment (option for correcting defective
vision) of -2.75 dpt to +3.75 dpt. It can be
adjusted for each eye individually. You can
also use the diopter adjustment to adapt
the glasses to various distances.
Position yourself at the desired distance
and put on your maxEVENT.
Keep your left eye closed and turn the
knurled ring q until your right eye can
see in sharp focus. Do the same for the
other eye.
Notes
Under the following circumstances, it
might not be possible to see the image
perfectly:
– If the maxEVENT is bent open too far,
for example due to an unusually large
head, doubled images might occur, be-
cause the optical axes of the two lens
systems are not in parallel anymore.
– A very small or very large pupil spacing
(eye spacing) can reduce the perfor-
mance quality, because the image is
not viewed through the optical zones
of the maxEVENT anymore.
– If you normally have glasses with
diopters of less than -2.75 diopters or
greater than +3.75 diopters, the diopter
adjustment feature of the maxEVENT
cannot entirely compensate the defec-
tive vision.
– If you usually wear glasses with
cylindrical lenses (e. g. for astigmatism),
it might not be possible to achieve
perfect focus. This depends on the
strength of the cylinder.

Care instructions

maxEVENT is a high-quality, technologi-
cally advanced, complex optical aid and
needs to be handled and cared for accord-
ingly. For protection of the mirror coating
and the lenses against dust and external
influences, we recommend that you store
it in the case included.
z Do not use alcohol or organic sol-
vents to clean the maxEVENT.
z Do not clean the maxEVENT in an
ultrasonic bath!
Clean the maxEVENT with a soft cotton
or linen cloth (such as cleaning cloths for
eyeglasses). Moisten the cleaning cloth to
remove more persistent stains (e.g. finger
marks). Do not rub the sensitive mirror
coating with a dry cloth.

Technical data

Article number
Diopter adjustment for
each eye individually
Magnification
Field of vision
Pupil spacing
Weight
- 6 -
162431
-2.75 dpt to
+3.25 dpt
2.1 ×
320 m / 1000 m
60 mm – 68 mm
49 g

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

162431

Tabla de contenido