ASSEMBLy
Open the packaging and check the condition of all the parts of the automation.
Construct a fastening pad in reinforced concrete and sink the anchoring base with tangs (optional)
fastened with the nuts provided.
Check that it is perfectly level and that the cable passage sheaths cross the centre hole of the
counter-plate.
Position the barrier and check that there are no obstacles to the movement of the rod.
ATTENTION: never move the barrier rod for any reason until it is horizontal, and do not per-
form the emergency or manual manoeuvre if the rod is not installed.
UNLOCK
If you need to perform manual actions on the barrier rod,
proceed as follows:
•
Cut the power supply.
•
Insert the release key provided and remove the latch,
insert the Allen wrench and turn it 90° (see fig. 2 ref. D).
•
In this way you can detach the internal reduction sys-
tem to allow the emergency manoeuvre.
•
Perform the manual manoeuvre.
•
To engage the transmission again, turn the Allen
wrench back to its original position and close the lock.
•
You can now restore the power supply and check that
everything is working correctly.
ADJUSTMENT OF ROD ANGLE
If you need to adjust the stops of the rods, proceed as follows:
•
Loosen the locking nut (located on the box for BEVK4 or on the rocker arm for BEVK6).
•
Adjust the screw to the desired height.
•
Fasten the locking nut back in place.
Loosen the lock nut
Adjust the screw to the desired height.
Fasten the lock nut.
12