17 Zone 1 Delay
18 GND
19 Zone 2 Instant
20 Zone 3 Instant
21 GND
22 Zone 4 Delay
23 Zone 5 Instant
24 GND
25 Zone 6 Instant
26 Zone 7 Delay
27 GND
28 Zone 8 Instant
Programming jumpers
System setting: Key Switch (KS) or Digital Keypad (DK).
KS: for systems with only key switch arm/disarm control (not applicable for
HAM263D)
DK: for systems with digital keypad and combined keypad/key switch control.
This jumper sets the time for the entry delay. This is the time between arming the
partition/zone and the beginning of detection in that zone. Entry delay is used in
zones 1, 4 and 7 and can be set to 15, 30, 60 or 90 seconds.
This setting determines the duration of the output signal on contact 7, and thus the
duration of the activation of connected devices e.g. siren, bell .... Possible options are
3, 5 or 15 minutes, or indefinite (until manual reset).
It is strongly advised not to use the indefinite option when using sirens or bells. Many
local authorities do not allow it.
These 3 jumpers control the entry, exit and warning beeps.
The entry beep sounds during the entry delay period
The exit beep sounds during the exit delay period
The warning beep depends on the status of the system:
a. Only one partition armed. Warning beep sounds during alarm and resets after
alarm expiration time.
b. Both partitions armed. Warning beep sounds during alarm and continues until
one of the partitions is disarmed.
With the handover function enabled, when zone 7 is triggered first, the instant zones
(except for the 24 hour instant zone) will set the same entry delay period as zone 7.
The instant zones will resume to instant mode after the entry delay time expires.
When another instant zone is triggered first, the alarm will sound instantly. This setup
allows that entry via one entrance (e.g. main door) delays the whole alarm system,
while attempts to enter via a different way will immediately trigger the alarm.
When set in the ON position, the ring-back function enables contact 7 twice for a short
while when the system is armed or ones when the system is disarmed. This produces
a sound signal through the connected siren or bell.
00 (10/10/2008)
Partition 1
Common ground for zone 1 and zone 2
Partition 1
Partition 1
Common ground for zone 3 and zone 4
Partition 2
Partition 2
Common ground for zone 3 and zone 4
Partition 2
Common, for common area e.g. lobby. Disarmed when either one of the
partitions is disarmed, only armed when both partition 1 and 2 are armed.
Common ground for zone 7 and zone 8
Common, 24 hour instant alarm. Cannot be switched off, except in standby
mode.
HAM263D
6