Remember that many types of equipment need extra consumption for startup.
Equipments that use an engine such as compressors, water pumps, circular
saws or others consume up to 3 times more power for startup. For example, a
1000W water pump will need 3000W to start up, therefore we would need a
generator no less than 3000W.

6.3 Oil alarm system.

The oil alarm system is designed to avoid engine damaged caused by an
insufficient amount of oil in the sump. Before the oil level in the engine sump is
below the safety limit, the oil alert system will shut the engine down
automatically.
NOTE: Protection due to lack of oil must be considered extreme safety. It
is the sole responsibility of the user to check the oil level before each use as
indicated in the manual. It is unlikely for this safety to fail, but if it does,
damage in the image would be very significant. The client would be solely
responsible for lack of maintenance and repair would be excluded from the
warranty.
Remember that it is a safety alarm in case of critical level, it is not a low oil
level indicator.
IMPORTANT: The alert system only acts in case of a level failure, it cannot
protect in case of inadequate oil or if it is in poor condition.
7. Stopping the engine
To stop the engine in case of an emergency, turn the engine switch off by
pressing to the "OFF" position.
Normal engine shutdown:
1 Unplug the electrical devices plugged to the generator.
2 Place the engine's switch to the "OFF" position
3 Turn the fuel valve to the Left, "OFF" position.