Vacuum Grid, Detergent Tank And Recovery Tank Cleaning; Solution Hose Filter Cleaning - Clarke Vantage 13 Libro De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VACUUM GRID, DETERGENT TANK AND RECOVERY TANK CLEANING

1.
Drive the machine to the appointed disposal area.
2.
Make sure that the power supply cable (10) is disconnected from the electrical mains.
3.
Open the transparent cover (A, Fig. 4) and clean it carefully.
Clean the vacuum grid (B) with care. If necessary disconnect the hoses (20 and 21).
4.
Check the transparent cover gasket (C) for integrity.
NOTE
The gasket (C) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (C) by removing it from its housing (A).
5.
Check that the seating surface (D) of the gasket (C) is integral and adequate for the gasket itself.
6.
Drain and wash the recovery tank (16) and the detergent tank (14) as shown in Use chapter.
7.
Install the tanks and the transparent cover with the vacuum grid.

SOLUTION HOSE FILTER CLEANING

1.
Drive the machine on a level ground.
2.
Make sure that the power supply cable (10) is disconnected from the electrical mains.
3.
Remove the solution hose plug (A, Fig. 5), carefully remove the hose from the tank and clean the fi lter (B) with water.
If necessary, remove the fi lter and replace it with a new one.
4.
Install the fi lter and the solution hose in the tank, then install the plug.
A
Operator's Manual - Vantage 13
A
C
B
D
Figure 4
Figure 5
ENGLISH
B
17
P100315
P100316

Publicidad