FLUE
for the smoke produced. The fact an old oven or stove
necessarily mean the new one will work well.
be taken into account in order to prevent incorrect smoke
tions indicated in the technical data.
stainless steel with smooth internal walls.
length (we recommend a minimum height of 3.5 - 4 m).
to collect solid material and any condensate. Dilapidated
galvanized steel, corrugated iron, etc.) with rough or
porous internal surfaces are illegal and detrimental to
stove operation.
obstructions, such as bottlenecks, horizontal sections and
sharp edges; any nonvertical sections should slope by not
faulty operation and avert the risk of unburnt deposits
at least once a year.
pressure drop between 0.12 and 0.2 mbars. Lower values
may lead to unpleasant smoke emissions when loading
the stove and produce excessive soot deposits; higher
values would lead to excessively fast combustion and a
values, refer to the UNI Standard 10683/2012 table.
be at least 2 metres away and the stove chimney pot
should be at least 40 cm higher than the others.
Please refer to the chapter of the UNI 10683/2012 regulation
regarding positioning of chimney pots.
duct.
SMOKE DUCT
The smoke duct must be made with steel or ceramic rigid
allowed. Horizontal and counterslope sections should be
avoided. Any cross-secion change should be made in corre-
1,2,3,4).
should be sealed with high temperature resistant mastic.
damper in the smoke duct.
SMOKE OUTLET

CHIMNEY POT

please refer to your retailer), an internal section
For correct operation, please refer toUNI 10683/2012.
-

TECHNICAL DATA

Available power
Hourly fuel consumption
Heatable volume
Weight BIG / packaging included
Weight GLAM / packaging included
Weight LUX / packaging included
Weight VIP / packaging included
Ø hot air outlet connection (male) n° 2
Air intake in place of installation: greater than
- 15
-
70,3
%
9,7
kW
3,6
kg/h
255
246
kg
256
kg
227
kg
246
kg
15
cm
10
cm
200
cm²