Mounting Instructions
2706-P42, 2706-P43 and
2706-P44
9. P1 can be used for incoming RS-232 only, although it is optional
and not recommended. P1 is intended for RS-232 application
downloads and RS-485 terminating resistor connection. See
publication 2706-IN007 for more information on RS-485
P1
termination.
Incoming
serial wires
TIP
10. To maintain NEMA compliance and to prevent EMI emissions,
install hole plugs in any open conduit holes in the power supply
enclosure. If needed, there is an extra hole plug supplied in
addition to any hole plugs removed in Step 2 on page 2.
11. Replace the power supply cover using the 6 screws from when
the cover was removed. (Refer to Step 1 on page 2.) Torque the screws
to 2.7 Nm (24 in-lb).
12. Connect the power cable to a power source.
TIP
Before mounting a sign, remove power from the sign.
Be sure to place the wires so they are not caught by
screws when replacing the power supply cover, and
also so they do not interfere with fan operation.
Only qualified personnel should install the InView
signs.
InView signs are for indoor use only and should not
be continuously exposed to direct sunlight.
Mounting hardware that is used to hang or suspend
signs must be capable of supporting at least 4 times
the total weight of any/all signs mounted together.
For integrity of the case, do not drill holes in or
modify the case.
InView Marquee Message Display
Publication 2706-IN006E-EN-P
5