Connections For Static Ignitions - Primary; Connections For Ignitions With Distributor - Secondary (Present Only On Sl31205/Plus); Connections For Static Ignitions - Secondary (Present Only On Sl31205/Plus); Secondary Diagnostics Connections In Static Ignitions Without High Voltage Cables - Spark Plug Coils (Present Only On Sl31205/Plus) - Tecnotest SL31205 Manual Operativo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 127
______________________________________________________________________ OSCILLOSCOPE KIT
2.5 -

Connections for static ignitions - primary

To connect the oscilloscope to the vehicles with DIS ignition, carry out the following
operations:
Connect the ground cable (5) to ground the system.
Connect the oscilloscope cable (1) to the cable of primary 1 or 2.
2.6 -
Connections for ignitions with distributor - secondary
(present only on SL31205/PLUS)
To connect the oscilloscope to vehicles with ignition with distributor carry out the
following operations:
Connect the ground cable (5) to ground the system.
Connect the capacitive clamp (20) to the high voltage central cable of the
distributor.
2.7 -
Connections for static ignitions - secondary
(present only on SL31205/PLUS)
To connect the oscilloscope to the vehicles with DIS ignition, carry out the following
operations:
Connect the ground cable (5) to ground the system.
Connect the capacitive clamp (20) to the cables of the single spark plugs, one by
one.
2.8 -
Secondary diagnostics connections in static ignitions
without high voltage cables – spark plug coils
(present only on SL31205/PLUS)
Connect the ground cable (5) to ground the system.
Place the oscilloscope cable point (1) close to the single static coils (Fig. 1) in the
point where the signal is stronger (see chapter 9.2).
OPERATING INSTRUCTIONS
41