40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Recommended Wall Outlet Installation
Locations
Suggested location of the wall outlet is shown in
Figure 4. The outlet may also be located in the lower
left corner of the adjacent right cabinet, as shown in
Figure 5.
20"
(50.8 cm)
10"
(25.4 cm)
7" Max.
(17.8 cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
Figure 4: Outlet location behind range
Figure 5: Adjacent cabinet outlet location
Center
Line of
Range
10"
(25.4 cm)
W A L L
Center
Line of
Range
8"
(20.3 cm)
12"
(30.5 cm)
3

Power Supply Cord

Electrical Shock Hazard –Do not attempt to install
the appliance directly to a junction box, modify the
factory-installed cord, or connect a different power
cord to the appliance. If the wall outlet is not sufficient
to support the requirements of this appliance, it is the
responsibility of the consumer to have the appropriate
outlet installed by an electrician. Improper installation
and electrical connections can result in electric shock,
damage to the appliance, personal injury, fire, or death.
This appliance is equipped with a factory-connected,
4-wire power supply cord (Figure 6). This cord is rated
at 240 volts, 40 amps, and temperature rated at 194°F
(90°C). This cord is UL/CSA listed and has been tested
and approved for use with this appliance.
Figure 6: Factory connected power supply cord
Appliance Rating*
120/240 Volts 120/208 Volts Amps
0-10 kW
0-7.6 kW
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
* The NEC calculated load is less than the total connec-
ted load listed on the serial plate.
8
Power Supply Rating
30
40 or 50
50