TROUBLESHOOTING

PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason
Poor contact with battery, inverter
PROBLEM: Inverter Auto Shut Down – Fault LED Lit
Reason
Battery voltage is below rated value.
Inverter is too hot (thermal shut down mode).
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason
Equipment being operated draws too much power.
PROBLEM: Inverter Shut Down – Yellow LED Lit
Reason
GFCI Tripped.
PROBLEM: Continuous Buzzing Sound
Reason
Input voltage is below rated value.
Poor or weak battery condition.
Poor or loose cable connection.
Inadequate power being delivered to the inverter or
excessive voltage drop.
15
®
Solution
terminals.
Clean terminals thoroughly. Reinstall and tighten.
Solution
Charge or replace battery.
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to the specified
TrueRated
Solution
Do not use the equipment with this inverter; use a
higher wattage inverter.
Solution
Disconnect appliances. To reset, turn off ON/OFF
switch and turn back on.
Solution
Keep input voltage above rated value.
Recharge or replace battery.
Inspect terminals and tighten all connections.
Use heavier gauge DC cables.
Keep cable length as short as possible.
www.wagan.com
power max output.