Slimline
Power Inverters by Wagan Tech
™
TROUBLESHOOTING
Reason
Poor contact with battery or inverter
terminals.
PROBLEM: Inverter Automatically Shut Down – Fault LED Lit
Reason
Battery voltage below 10V
Inverter is too hot.
(Thermal protection mode.)
Unit may be defective.
Equipment being operated draws too much
power.
PROBLEM: Pulsing Alarm
Reason
Input voltage below 10.5V
Poor or weak battery condition.
Poor or loose cable connection.
Inadequate power being delivered to the
inverter or excessive voltage drop.
DISPOSAL/RECYCLING OF INVERTER
Electronic products are known to contain materials that are toxic if improperly disposed. Contact
local authorities for disposal and recycling information.
9
®
Solution
Clean terminals thoroughly. Reinstall and
tighten.
Solution
Charge or replace battery.
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to rated
continuous power output.
See warranty and call customer service.
Use a higher capacity inverter or do not use
this equipment.
Solution
Keep input voltage above 10.5V
Recharge or replace battery.
Inspect terminals and tighten all connections.
Use heavier gauge DC cable.
Keep cable length as short as possible.
www.wagan.com