flat surfaces. Use caution when rolling on carpeted surfaces. Use caution and
Protect floors when rolling over wood floors. Do not attempt to roll the unit
over objects.
• The unit must be placed within reach of a properly rated grounded socket.
• Never place any obstacles around the air inlet or outlet of the unit.
• Allow at least 45cm of space away from the wall for efficient air conditioning.
• The hose can be extended, but it is the best to keep the length to minimum
required. Also make sure that the hose does not have any sharp bends or sags.
INSTALLATION INSTRUCTIONS
EXHAUSTING HOT AIR
In the Cool Mode the appliance must be placed close to a window or opening
so that the warm exhaust air can be ducted outside.
First position unit on a flat floor and make sure there's a minimum of 12"
(30cm) clearance around the unit, and is within the vicinity of a single circuit
outlet power source.
1
Extend either side of the hose {Fig.1 )and screw the hose inlet (Fig.2).
2
Extend the other side of the hose and screw it to the hose outlet (Fig.3).
Fig. 1
3
Install the hose inlet into the unit (Fig.4).
4
Affix the hose outlet into the window slider kit and seal. (Fig.5 &6).
Fig. 2
Lock
Fig. 3
Slide onto
Your window slider kit has been designed to fit most standard vertical
Vertical
Window
and horizontal window applications, however, it may be necessary for you
to modify some aspects of the installation procedures for certain types of
windows. The window slider kit can be fastened with screws.
G
Window slider
If the window opening is less than the minimum length of the window
slider kit, cut the end without the hold in it short enough to fit in the
Fig. 5
window opening. Never cut out the hole in window slider kit.
Horizontal
Window
WINDOW SLIDER KIT INSTALLATION
1 Parts:
Window slider
A) Panel
B) Panel with one hole
Fig. 6
C) Panel without hole (maybe not supplied)
4
52
Cut on opposite
side of hole.
Fig. 4
D) Screw to lock window kit in place
2 Assembly:
Slide Panel Band C into Panel A and size to widow width. Windows sizes
vary. When sizing the window width, be sure that the window kit assembly is
free from gaps from gaps and/or air pockets when taking measurements.
3 Lock the screw into the holes that correspond With the width that your
window requires to ensure that there are no gaps or air pockets in the
window kit assembly after installation.
D
DESCRIPTION OF THE DISPLAY SCREEN
1. COOL symbol
2. HEAT symbol*
3. FAN Speed indicator
4. TIMER symbol
5. Temperature symbol
6. Temperature indicator
* means only the heat pump model have this function.
OPERATING FROM THE CONTROL PANEL
The control panel is on the top of the appliance, enables you to manage part
functions without remote controller, but to fully exploit its potential, you
must use the remote controller.
1 ON/OFF button
2 MODE button
3 FAN button
4 INCREASE button
5 DECREASE button
TURNING THE APPLIANCE ON
Plug into the mains socket, then the appliance is standby. Press the
button
4
53