Descargar Imprimir esta página

Electrical Safety - Imer Group MOVER 190D Manual De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

- Before using the screed pump make sure the protection
devices have not been removed. In particular, make sure the
safety device connected to the opening of the grill located
opened - works correctly and that the safety device with ball
perfectly clean.
1
FIG.2
- When the pipes are connected to the tank material deli-
very manifold, their ends must always be connected to the jet
breaker stand: this must not be removed for any reason.
- Always relieve the tank pressure before opening
the hatch or disconnecting the pipes: the pressure gauge
there is no sound of air escaping before opening the hatch.
- As well as completely discharging the pressure from
the tank, squeeze the pipes to make sure there is no residual
pressure inside before disconnecting them. In case of any
residual pressure, wait for it to discharge naturally, if neces-
sary, striking the pipes with a rubber mallet at the places
where stoppages have formed.
- Turn the machine off before accessing the tank.
- The casing must be closed by key during use
- Always switch off the Diesel engine before opening the
casing.
- Pay attention when opening the casing, because there
inside the engine compartment.
The accident-prevention regulations and safety instructions must
be observed in the work area.
In particular, there must be a completely free area of at least 1
the machine operator stands.
When using the loading the bucket and scraper, the operator must
constantly ensure that no one else is near the work area.
Take care when handling bags of material, and avoid creating
sprays which could come into contact with eyes or other parts
of the body. Wear safety glasses and gloves. Do not raise dust,
which could be inhaled. Always wear a mouth and nose mask
during use.
- The machine must not be used in places where there is
The screed pump does not have its own lighting, therefore the
workplace must be adequately lit.
IMER INTERNATIONAL S.p.A.

6. ELECTRICAL SAFETY

The MOVER 190 D SCREED PUMP has a12 Vdc electrical
system.
7. MECHANICAL SAFETY
The hazardous parts of the IMER screed pump are protected
perfect condition, such as the Diesel engine cooling fan guard
and the grill on the tank collar, that prevents contact with the mixer
located inside the tank. This is interlocked with a safety ball
opened.
2
any reason: tampering with the grill is the most frequent cau-
se of serious work accidents with these types of machines.
Before moving the screed pump, it is advisable to lift the bucket
and disconnect the material delivery pipe and, if present, the pres-
sure water cleaner suction and delivery hoses. This must always
be done when lifting the machine.
There must also not be any material in the tank or
in the loading bucket.
-
litate moving the machine by hand in the worksite. Only the
version with approved towing set-up is suitable for towing.
disconnect the material delivery pipe and, if present, the
scraper and the pressure water cleaner hoses. The scraper
must be carried separately.
sure all components of the machine are correctly secured
the safety pin.
To lift the machine, use the four special points provided on top of
hook B is for the machine WITH bucket.
sway.
Use lifting equipment suitable for the overall weight of the machine
indicated in table 1.
21
- The grill must not be tampered with in any way or for
A
B
FIG.3
- Important! The purpose of the drawbar is only to faci-
- Important! Before lifting the screed pump, always
- Important! Before lifting the screed pump, always make
- The bucket must always be secured with the safety pin.
Hook A is for the machine WITHOUT bucket;
- Caution! Lift carefully because the machine can easily
- Caution! Never use points different from those indica-

Publicidad