If an Exhaust Hood Cannot be Used
The outside end of main vent should have a sweep elbow
directed downward.
12" min.
(305 mm)*
* Minimum clearance above any
accumulation of snow, ice, or
debris such as leaves
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
2 ft. (610 mm) above surface of roof.
Theopeninginwallorroofshallhaveadiameter1/2"(13mm)
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.

Make Gas Connection

Remove red cap from gas pipe on back of dryer.
1.
2. Connect gas supply to dryer. Use a pipe thread compound
approvedforthetypeofgassupplied.Ifflexiblemetal
tubing is used, be certain there are no kinks.
If necessary for service, open the front lower service panel
byusinga1/4"nutdrivertoremovethetwohex-headscrews
from the bottom of the panel. Then lift up on the panel while
pulling the bottom of the panel away from the dryer.
24" min.
(610 mm)
DRYER VENTING REQUIREMENTS
Multiple Dryer Venting
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 l/min. (200 CFM)
of air per dryer. Large-capacity lint screens of proper design
may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air equal to or greater than CFM of all the dryers in the room.
Back-draft Damper Kit is available from your distributor and
should be installed in the vent of each dryer to keep exhausted
air from returning into dryers and to keep exhaust in balance
within main vent. Unobstructed return air openings are required.
Each vent should enter the main vent at an angle pointing in the
directionoftheairflow.Ventsenteringfromtheoppositeside
should be staggered to reduce the exhausted air from interfering
with the other vents.
Air Flow
air ow
The maximum angle of each vent entering the main vent should
be no more than 30.°
Keepairopeningsfreeofdrycleaningfluidfumes.Fumescreate
acids which, when drawn through the dryer heating units, can
damage dryers and items being dried.
A clean-out cover should be located on the main vent
for periodic cleaning of the vent system.

GAS SUPPLY CONNECTION

3.  O pentheshut-offvalveinthegassupplylineandmakesure
the dryer has its own gas supply opened.
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leaks found.
30˚ max.
15