3. Specifications
3. Specifications
3.1 Transducer model LSO.06
GB
General data
Measuring accuracy
Ambient light
Mounting position
Weight
Standard version
■
High and low temperature version
■
1) ML = Measuring length
Design data
Medium temperature
Standard version
■
High and low temperature version
■
Ambient temperature
Working pressure
High pressure version
Materials
Sensor case
■
Light guide
■
Packing
■
Case
■
Ex ignition protection type
Electrical data
Cable gland
Terminal connection
Ingress protection
For further specifications see WIKA data sheet LM 31.10 and the order documentation.
10
±0.5 mm
max. 100 Lux
any
0.77 kg +9.3 g/cm ML
1.07 kg +9.3 g/cm ML
-65 ... +250 °C
-269 ... +400 °C
-65 ... +95 °C
0 ... 25 MPa (0 ... 250 bar)
0 ... 50 MPa (0 ... 500 bar)
1.4571 (option: hastelloy, other materials on request)
clad core glass (option: quartz, sapphire (only max.
ML = 60 mm))
graphite
stainless steel
II 1/2 G Ex ib op is IIC T5, T6
T6: to 60 °C, T5: to 75 °C
ZELM 10 ATEX 0440
M20 x 1.5, Ex: blue
3 x 2.5 mm²
IP 65 per EN 60529
WIKA operating instructions models LSO.06, LSO.25
1)
1)