After the preliminary programming by the TPE, the advanced programming will be carried out through
the means of the integrated SIG7720 WEB MANAGEMENT interface. (NOTE: WEB interface could
vary depending on the Firmware version loaded in the module).
Before starting the programming, make sure that the Controller Host (SIG7905) module, if any, is in
Slave mode.
The procedure is as follows:
1. From the properties of the PC local network card, modify the IP address, setting a new address
belonging to the same sub-network of the SIG7720 module address set. For example:
a. Parameter set in the streamer
i. IP: 192.168.0.2 (factory address)
ii. SUBNET MASK: 255.255.255.0
iii. GATEWAY: 192.168.0.1
b. Parameters to be set in the properties of the network card
i. IP: 192.168.0.3
ii. SUBNET MASK: 255.255.255.0
iii. GATEWAY: 192.168.0.1
2. Connect the PC to the module by means of a cross RJ-45 cable of CAT-5E;
3. Open the Internet browser (Recommended Browser Internet Explorer vers. 7.0 or superior);
4. Enter the IP associated to the SIG7720 in the address bar; the following HOME PAGE is displayed.
Select the language for the WEB Interface (English, Français, Deutsch, Italian, Espanol, Portugues).
From this menu, the following options can be selected:
HOME --> Initial page of the integrated WEB configuration device;
INPUT --> program the input parameters of the receiver associated to the SIG7720 module. Look at
the coupling condition of the receiver displayed and loop it through to other enabled SIG7720 modules;
PROGRAM LIST --> Display menu and setting menu for TV programs sent to the network (program list,
selection of IP multicast groups, etc);
MULTICAST --> Setting of the MULTICAST groups;
NETWORK --> Setting of the module IP parameters;
5.3 SIG7720 WEB MANAGEMENT PROCEDURE
34