Valve Control With Remote Bus Module (Ip69K) - Aventics VS CL03 Instrucciones De Servicio

Ocultar thumbs Ver también para VS CL03:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3
2
1
13
12
11
Fig. 11: Connecting a remote bus module and add-on bus module
AVENTICS | CL03/CL03-XL | R402000141–BDL–001–AE

6.4.2 Valve control with remote bus module (IP69K)

Follow the steps below for VS CL03/CL03-XL with remote bus
module (IP69K only). See Fig. 11.
1. Fit the mounting plate (1) supplied with the bus module (3)
to a grounded back plate.
2. Connect the bus module (3) to the VS (10) with the cable (12)
whose other end is the multipole plug (9) fitted to the VS.
3. Ensure that the seal (13) is fitted correctly and tighten the
plug screws (11). Tightening torque 0.7 Nm.
4. Connect the bus module to the control system according to
the manual for the respective bus module.
4
5
2
6
7
Assembly
8
9
10
83

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vs cl03-xl

Tabla de contenido