The air heater is delivered complete, factory
assembled apart from external components listed
below. These components can be included in the
delivery, but the assembly or connection has to be
done at the installation site:
• exhaust pipe system (available only on request);
• room or remote thermostat (available only on
request);
• farm controller (available only on request).
The control panel components and features are as
in
.
WARNING
Use only the approved burner
components supplied by the manufacturer of the air
heater. If the burner is replaced by one that is not
approved by the manufacturer of the air heater,
even if it has similar feature then, this is considered
improper use of the machine and could cancel the
CE marking.
GFn is designed to deliver heating output: 80 kW
(detailed info see Appendix). The stated heating
output data must be interpreted as approximate and
not absolute reference, because it is subject to
possible variations due to tolerances of the
elements taken as reference and, in some cases,
modification
of
the
manufacturers
notice.
environmental conditions are important as well, so
the altitude, atmospheric pressure, relative humidity
and environmental temperature might also affect
these values.
NOTE
The exhaust piping system is not delivered
as standard, it is available on request.

3.4 Storing

When the air heater is not going to be installed
immediately after delivery or it has to be stored for a
long period of time then, it is important to follow
these rules and guidelines:
• store the air heater properly even when it is not
used;
• the permissible ambient temperature range for
storing is 0°C to +70°C, with maximum relative
humidity of 80%;
• place the air heater on stable horizontal and flat
surface;
• make sure the air heater are protected from
possible damage;
• store the air heater in a dry place under cover,
protected from elements of nature including dust,
frost, rain, snow and aggressive contaminants;
• in case of long term storage it is recommended to
manually rotate the fan regularly to prevent
failure;
• stack the air heater as indicated on the
packaging. At maximum 3 packaged heaters can
be stacked.
burner
elements
without
The
climatic
6
WARNING
lead to crushing hazard. Use proper measures to
secure the stacked air heaters.

4. OPERATING CONDITIONS

The user shall perform the task of preparing a
suitable operating space for the heater which fulfills
the requirements of the European directives and
national
regulations
workplace.
WARNING
in areas where the entrance and access of people
younger than 14 years old is forbidden. Do not
install or operate the air heater in areas where
sulphurator devices or machines are used.
The operating conditions for the GFn air heaters
installed indoor or outdoor are:
Operating mode
Ambient temperature
Ambient humidity
and
Altitude above sea level
NOTE
When using the standard air heater at
elevations close to 1000 m, air supply adjustment
periodic monitoring and additional maintenance by
qualified technicians are necessary to assure proper
functioning and correct exhaust emissions.
Low ambient temperature cause fuels to gel or
condensate. If gelled or compensated fuels reach
the burner then, the ignition fails and/or internal
components (e.g. fuel pump, gas train) are
damaged. The user must ensure proper fuel state
for all conditions all times.
For mechanical ventilation e.g. exhaust fans, the
minimum ventilation requirement is 800 m
cfm) for each GFn unit installed.
NOTE
Exhaust
appropriate cycle during the heating sequence, to
avoid high concentrations of carbon monoxide and
water vapor, especially during the cold season e.g.
to seal the poultry structure to conserve the heat,
prior to the arrival of the livestock, etc.
For natural ventilation, the minimum ventilation shall
be assured by a permanent free opening area of 0.5
2
m
for each GFn unit installed.
The minimum ventilation requirements may vary in
case of other heating equipment is installed in the
same
structure
ventilation
assessed before calculating the necessary natural
|
© Munters AB, 2019
Improperly stacked air heater can
governing
The GFn air heater must be installed
Heating
0°C to
+40°C
Maximum 1,000 m
fans
should operate
with
the
GFn
requirements
should
safety
in
the
Ventilation
0°C to
+50°C
Max 90%
3
/h (470
on
an
heaters.
The
be
properly