English
(2) Continuous operation (Push lever fire)
Using CONTACT ACTUATION MECHANISM
● To avoid double firing or accidental firing due to recoil.
1) Do not press the nailer against the wood with excessive force.
2) Separate the nailer from the wood as it recoils after nailing.
1 Set the switching device to the downward position (to set to CONTACT ACTUATION
MECHANISM).
(Set the switching device to the downward position completely as shown in the
diagram. Otherwise, it will not operate properly.)
2 Pull the trigger with the Nailer off the workpiece.
3 Depress the push lever against the workpiece to drive a nail.
4 Move the Nailer along the workpiece with a bouncing motion.
Each depression of the push lever will drive a nail.
As soon as the desired number of nails have been driven, remove finger from the
trigger.
1 Downward position
● Keep your finger off the trigger except during fastening operation,
beacuse serious injury could result if the push lever accidentally
contacts you or others in work area.
● Keep hands and body away from the discharge area. This Hitachi
nailer may bounce from the recoil of driving a fastener and
unwanted subsequent fastener may be driven, possibly causing
injury.
THE FULL SEQUENTIAL ACTUATION MECHANISM (SEQUENTIAL TRIP MECHANISM)
is for use where precision fastener placement is desired and must be operated in
accordance with the following "Method of Operation".
20
WARNING
Valve Bush
Switching Device
WARNING
Previously pull the trigger
2
4