HOW TO PREPARE THE MACHINE FOR
OPERATION
WARNING: Always remove the electrical
plug from the electrical outlet before
installing or changing the pad or brush.

How To Install The Brush Or Pad Driver

To install the brush or pad driver, follow this
procedure:
1. Put the handle in the vertical position.
2. To lock the handle, push the locking lever
down. See figure 1.
3. Tilt the machine backward until the handle is on
the floor. See figure 2.
4. Put one foot on each side of the machine. See
figure 2.
5. Align the lugs (1) on the locking plate into the
pad driver adapter openings (2). See figure 3.
6. To lock the brush or pad into position, turn the
brush or pad driver as indicated in figure 2 (A).
7. To unlock and remove the brush, turn the brush or
pad as indicated in figure 2 (B).
8. Lift the machine to the vertical position.
NOTE: To prevent damage to the brush or pad
driver, remove the accessory while not in use.
Keep the brush in a cool, dry place.

How To Adjust The Handle

To adjust the handle, follow this procedure:
1. The locking lever is on the lower part of the
handle tube. Use your foot to lift the lever.
2.
Lower the handle to the best operating position.
NOTE: For the best operating position, keep your
back straight, bend only your arms.
3. Using your foot, push the locking lever down.
4. Hold the handle against your body for the best
control.
-6-
FORM NO. 71399A
Figure 1
A
Figure 2
1
2
Figure 3
1. The lugs.
2. The drive adapter openings.
Clarke
®
B
MP-1800 -