Figure 15
WARNING
Pay great attention when dismantling the individual parts of the hydraulic assembly.
Do not use sharp tools, do not apply excessive force when removing the fixing clip.
33. DISASSEMBLING THE BOILER ANODE
Check the state of the protective magnesium anode on
an annual basis
(before proceeding, empty the boiler circuit using the
relevant drain tap).
To disassemble the anode unit remove the boiler sensor
fixing clip, take it out and with a 27mm spanner (A) and
loosen the anode support nut.
A
INSTALLATION INSTRUCTIONS
71.06199.02 - EN
82